:Coupled fluid-thermal investigation on non-ablative thermal protection system with spiked body and opposing jet combined configuration论文

:Coupled fluid-thermal investigation on non-ablative thermal protection system with spiked body and opposing jet combined configuration论文

本文主要研究内容

作者(2019)在《Coupled fluid-thermal investigation on non-ablative thermal protection system with spiked body and opposing jet combined configuration》一文中研究指出:In this paper, a Non-Ablative Thermal Protection System(NATPS) with the spiked body and the opposing jet combined configuration is proposed to reduce the aerodynamic heating of the hypersonic vehicle, and the coupled fluid-thermal numerical analysis is performed to study the thermal control performance of the NATPS. The results show that the spiked body pushes the bow shock away from the protected structure and thus reduces the shock intensity and the wall heat flux. In addition, the low temperature gas of the opposing jet separates the high temperature gas behind the shock from the nose cone of the spiked body, ensuring the non-ablative property of the spiked body. Therefore, the NATPS reduces the aerodynamic heating by the reconfiguration of the flow field, and the thermal control efficiency of the system is better than the Thermal Protection System(TPS) with the single spiked body and the single opposing jet. The influencing factors of the NATPS are analyzed. Both increasing the length of the spiked body and reducing the total temperature of the opposing jet can improve the thermal control performance of the NATPS and the nonablative property of the spiked body. However, increasing the heat conductivity coefficient of the spiked body can enhance benefit the non-ablative property of the spiked body, but has little influence on the thermal control performance of the NATPS.

Abstract

In this paper, a Non-Ablative Thermal Protection System(NATPS) with the spiked body and the opposing jet combined configuration is proposed to reduce the aerodynamic heating of the hypersonic vehicle, and the coupled fluid-thermal numerical analysis is performed to study the thermal control performance of the NATPS. The results show that the spiked body pushes the bow shock away from the protected structure and thus reduces the shock intensity and the wall heat flux. In addition, the low temperature gas of the opposing jet separates the high temperature gas behind the shock from the nose cone of the spiked body, ensuring the non-ablative property of the spiked body. Therefore, the NATPS reduces the aerodynamic heating by the reconfiguration of the flow field, and the thermal control efficiency of the system is better than the Thermal Protection System(TPS) with the single spiked body and the single opposing jet. The influencing factors of the NATPS are analyzed. Both increasing the length of the spiked body and reducing the total temperature of the opposing jet can improve the thermal control performance of the NATPS and the nonablative property of the spiked body. However, increasing the heat conductivity coefficient of the spiked body can enhance benefit the non-ablative property of the spiked body, but has little influence on the thermal control performance of the NATPS.

论文参考文献

  • [1].New Solutions for Some Planar N-body Problems[J]. 张世清.  数学进展.2004(04)
  • [2].Shock-stable flux scheme for predicting aerodynamic heating load of hypersonic airliners[J]. Feng Qu,WeiXuan Kong,Di Sun,JunQiang Bai.  Science China(Physics,Mechanics & Astronomy).2019(08)
  • [3].Structure overset grid method and its applications to simulation of multi-body separation[J]. ZHANG HaiRui,FAN JingJing,YUAN Wu,ZHANG WeiHua.  Science China(Physics,Mechanics & Astronomy).2015(09)
  • [4].Flow Patterns and Thermal Drag in a One-Dimen-sional Inviscid Channel with Heating or Cooling[J]. Yuwen Zhang Yonglin Ju Department of Power Machinery Engineering, Xi’an Jiaotong University, Xi’an 710049, China.  Journal of Thermal Science.1993(04)
  • [5].A computational study of the wing-wing and wing-body interactions of a model insect[J]. Xin Yu Mao Sun Institute of Applied Physics and Computational Mathematics,Beihang University, 100191 Beijing, ChinaInstitute of Fluid Mechanics, Beihang University,100191 Beijing, China.  Acta Mechanica Sinica.2009(04)
  • [6].Interface delamination of the thermal barrier coating subjected to local heating[J]. WU ChenWu, HUANG ChenGuang & CHEN GuangNan Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China.  Science China(Technological Sciences).2010(12)
  • [7].CALCULATING METHOD OF AERODYNAMIC HEATING FOR HYPERSONIC AIRCRAFTS[J]. 季卫栋,王江峰.  Transactions of Nanjing University of Aeronautics & Astronautics.2013(03)
  • [8].Numerical investigation of windage heating within shrouded rotor-stator cavity system with central inflow[J]. WANG Qian-shun,ZHANG Da,LUO Xiang,XU Guo-qiang.  航空动力学报.2014(10)
  • [9].Comparisons and applications of numerical simulation methods for predicting aerodynamic heating around complex configurations[J]. Jin-Ling Luo · Hong-Lin Kang · Jian Li · Wu-Ye Dai Northwestern Polytechnical University,710072 Xi’an,China Beijing Electro-Mechanical Engineering Institute,100074 Beijing,China.  Acta Mechanica Sinica.2011(03)
  • [10].MHD natural convection with Joule and viscous heating effects in iso-flux porous medium-filled enclosures[J]. Y.M.AL-BADAWI,H.M.DUWAIRI.  Applied Mathematics and Mechanics(English Edition).2010(09)
  • 论文详细介绍

    论文作者分别是来自Chinese Journal of Aeronautics的,发表于刊物Chinese Journal of Aeronautics2019年06期论文,是一篇关于,Chinese Journal of Aeronautics2019年06期论文的文章。本文可供学术参考使用,各位学者可以免费参考阅读下载,文章观点不代表本站观点,资料来自Chinese Journal of Aeronautics2019年06期论文网站,若本站收录的文献无意侵犯了您的著作版权,请联系我们删除。

    标签:;  